Search Criteria Used (More)

Compania Cervecera de Puerto Rico, Inc.

Searching...


Facility #1 : Compania Cervecera De Puerto R


Basic Facility Info facility_Basic_Facility_Info help link help link  
Facility ID100000182312
Deregistered (Yes/No)No
Facility NameCompania Cervecera de Puerto Rico, Inc.
Street Address Line 1100 Blvd. Alfonso Valdez
CityMayaguez
StatePR
Zip Code00680
CountyMayagŁez Municipio
113th Congressional DistrictPR98: Puerto Rico nonvoting
Owner or Operator NameLic. Camalia Valdez
Latitude18.206944
Longitude-067.141667
Number of RMP Submissions6

Most Recent Submission Info facility_Most_Recent_Submission_Info help link help link  
RMP ID1000034245
Submission Typerevised submission for facility
Submission Date05/06/2013
Reason For Submission5-year update (40 CFR 68.190(b)(1))
Process Toxic Amount Total (lbs)29,500
Process Flammable Amount Total (lbs)0
Process Amount Total (lbs)29,500
Number of Potential Offsite Consequence Processes1
Potential Offsite Consequence Toxic Amount Total (lbs)29,500
Potential Offsite Consequence Flammable Amount Total (lbs)0
Potential Offsite Consequence Amount Total (lbs)29,500
All Process NAICS31212 311213
Exec Summary Submission Date05/06/2013

Executive Summary facility_Executive_Summary help link help link (Facility #1 : Compania Cervecera de Puerto R, executive summary: all)

Executive Summary
Cerveceria India, Inc. is an established brewery in Mayaguez, PR, with 280 employees. The company is committed to comply with all applicable requirements for its beverage manufacturing operations. Cerveceria India uses one of the compounds which appear on the list of Risk Management Planning chemicals and which is stored in greater-than-threshold quantities. The facility operates an ammonia refrigeration system as part of its manufacturing operations. This Cold Block refrigeration system utilizes ammonia as a refrigerant in a closed system. *Prevention Program: Cerveceria India, Inc., has implemented a prevention program for the covered process. Hazard reviews have been conducted, and updated at least every five years to aid in identifying hazards and recommendations for improvement. Operators and maintenance personnel are trained and provided with written instructions as well as safe work practices. Training is provided at least every three years or more often if necessary. Contractors working in or adjacent to the refrigeration system receive training in applicable ammonia hazards and safe work practices. Cerveceria India, Inc. has developed procedures for maintaining the ongoing integrity of equipment. All incidents and near misses are investigated and recommendations resolved as soon as possible.

*Five Years Accident History: The facility had an accidental release on October 6, 2007. A release of carbon dioxide and ammonia from Cerveceria India, Inc. located at Mayagez, Puerto Rico, resulted in the evacuation of residential population within a 2 square mile area (2,000 people were e
vacuated in total). One employee and 36 residents required medical attention and/or hospitalization. Seven vessels, part of a carbon dioxide transfer system, failed and the resulting overpressure impacted an ammonia refrigeration system. The system failure resulted in a release of 85,000 lbs. of carbon dioxide and 18,074 lbs. of ammonia over a 3.5 hr. period.

*Emergency Response Program: Cerveceria India, Inc., has developed and emergency action plan to respond to minor fires and spills and for a safe plant evacuation. Cerveceria India, Inc. has coordinated emergency response through a private contractor specialized in response for this type of emergencies. Cerveceria India, Inc. is actually participating in the LEPC meetings and is committed to contribute to this program. *Planned Changes to Improve Safety: As part of the incident investigation, 23 recommendations were identified. Training and a Process Hazard Analysis of a new CO2 system have been completed. Also, improvements to the Emergency Response Plan and related equipment are being pursued.
Submission - Other Facility Info facility_Submission_-_Other_Facility_Info help link help link  
Number of Full Time Employees280
Owner or Operator NameLic. Camalia Valdez
Owner or Operator Address Line 1P.O. Box 1690
Owner or Operator CityMayaguez
Owner or Operator StatePR
Owner or Operator Zip00681
Owner or Operator Zip Extension1690
Parent Dun and Bradstreet Number0
Second Parent Dun and Bradstreet Number0
Number of Full Time Employees280
Number of FTE CBI FlagNo
Other Facility IDPR0001341 NPDES
Covered by OSHA PSM StandardYes
Covered by EPCRA Section 302Yes
Covered by CAA Title VYes
CAA Title V Air Operating Permit IDTV2082500597038
Last Safety Inspection Date03/31/2008
Last Safety Inspection ByState occupational safety agency
OSHA Star or Merit RankingNo
LEPC NameLEPC Region Mayaguez

Submission - Contact Info facility_Submission_-_Contact_Info help link help link (Facility #1 : Compania Cervecera de Puerto R, RMP submission #1 : 2013-05-06)
Owner or Operator Phone7878341000
Facility Dun and Bradstreet Number0
RMP ContactDwight Pagan
RMP Contact TitleEnvironmental Manager
RMP Contact Emaildwight.pagan@cerveceriaindia.com
RMP Preparer NameArlene Pagan, PE
RMP Preparer Address Line 1Paseo Los Robles
RMP Preparer Address Line 21837 Carlos Casanova St.
RMP Preparer CityMayaguez
RMP Preparer StatePR
RMP Preparer Zip00682
RMP Preparer Zip Extension7904
RMP Preparer Phone7878311136

Submission - Additional Info facility_Submission_-_Additional_Info help link help link  
RMP Complete FlagYes
Predictive FilingNo
No RMP Accidents Last 5 YearsNo
Complete Check Date05/06/2013
Postmark Date05/06/2013
Anniversary Date05/06/2018
Confidential Business InformationNo

Submission - Lat/Long Info facility_Submission_-_Lat_Long_Info help link help link (Facility #1 : Compania Cervecera de Puerto R, RMP submission #1 : 2013-05-06)
Latitude18.206944
Longitude-067.141667
Valid Lat/LongYes
Lat/Long MethodInterpolation - Photo
Lat/Long Location TypeProcess Unit Area Centroid
FRS Latitude18.2
FRS Longitude-67.14
FRS Lat/Long DescriptionFACILITY CENTROID
FRS Lat/Long MethodINTERPOLATION-PHOTO

Submission - Counts and Totals facility_Submission_-_Counts_and_Totals help link help link  
Number of RMP Accidents1
RMP Accident Flammable Total (lbs)0
RMP Accident Toxic Total (lbs)18,074
RMP Accident Amount Total (lbs)18,074
Number of RMP Accidents1
Number of Processes1
Number of Process Chemicals0
Number of Toxic Worst-case Scenarios1
Number of Toxic Alternate Case Scenarios1
Number of Flammable Worst-case Scenarios0
Number of Flammable Alternate Case Scenarios0
RMP Accident Flammable Total (lbs)0
RMP Accident Toxic Total (lbs)18,074
RMP Accident Amount Total (lbs)18,074
Total RMP Accident Deaths0
Total RMP Accident Injuries71
Total RMP Accident Evacuated/Sheltering In Place2,000
Total RMP Accident Property Damage$500,000

Processes facility_Processes help link help link (Facility #1 : Compania Cervecera de Puerto R, RMP submission #1 : 2013-05-06, process #1 : Cold Block Ammonia Refrig)
Process DescriptionCold Block Ammonia Refrig
Program Level3
Confidential Business InformationNo
Toxic Amount Total (lbs)29,500
Flammable Amount Total (lbs)0
Process Amount Total (lbs)29,500
Number of Process Chemicals0
Number of Toxic Worst-Case Scenarios1
Number of Toxic Alternate Scenarios1
Number of Flammable Worst-Case Scenarios0
Number of Flammable Alternate Scenarios0

Process Chemicals facility_Process_Chemicals help link help link  
Process Chemical IDAmmonia (anhydrous)
CAS number007664417
Chemical TypeToxic
Process Chemical Amount (lbs)29,500
Confidential Business InformationNo

Process Chemicals facility_Process_Chemicals help link help link (Facility #1 : Compania Cervecera de Puerto R, RMP submission #1 : 2013-05-06, process #1 : Cold Block Ammonia Refrig, process chemical #2)
Process Chemical IDPublic OCA Chemical
CAS number000000000
Process Chemical Amount (lbs)0
Confidential Business InformationNo

Worst-Case Toxic Scenarios facility_Worst-Case_Toxic_Scenarios help link help link  
Physical StateGas liquified by pressure
Model UsedAreal Locations of Hazardous Atmospheres [ALOHA(R)]
Release Duration (minutes)10
Wind Speed (meters/sec)1.5
Atmospheric Stability ClassF
TopographyUrban
Passive Mitigation - DikesNo
Passive Mitigation - EnclosuresNo
Passive Mitigation - BermsNo
Passive Mitigation - DrainsNo
Passive Mitigation - SumpsNo
Confidential Business InformationNo

Alternate Case Toxic Scenarios facility_Alternate_Case_Toxic_Scenarios help link help link (Facility #1 : Compania Cervecera de Puerto R, RMP submission #1 : 2013-05-06, process #1 : Cold Block Ammonia Refrig, process chemical #2, alternate toxic scenario #1)
Percent Weight (Within Mixture)100
Physical StateGas liquified by pressure
Model UsedAreal Locations of Hazardous Atmospheres [ALOHA(R)]
Wind Speed3.2
Atmospheric Stability ClassD
TopographyUrban
Passive Mitigation - DikesNo
Passive Mitigation - EnclosuresNo
Passive Mitigation - BermsNo
Passive Mitigation - DrainsNo
Passive Mitigation - SumpsNo
Active Mitigation - SprinklersNo
Active Mitigation - Deluge SystemsNo
Active Mitigation - Water CurtainNo
Active Mitigation - NeutralizationNo
Active Mitigation - Excess Flow ValvesNo
Active Mitigation - FlaresNo
Active Mitigation - ScrubbersNo
Active Mitigation - Emergency ShutdownNo
Confidential Business InformationNo

Process NAICS facility_Process_NAICS help link help link (Facility #1 : Compania Cervecera de Puerto R, RMP submission #1 : 2013-05-06, process #1 : Cold Block Ammonia Refrig, process NAICS code #1 : 31212)
NAICS Code31212: Breweries

Prevention Program 3 facility_Prevention_Program_3 help link help link  
Safety Info Review Date08/06/2007
PHA Update Date06/05/2008
PHA Technique - What IfNo
PHA Technique - ChecklistNo
PHA Technique - What If/ChecklistNo
PHA Technique - HAZOPYes
PHA Technique - FMEANo
PHA Technique - FTANo
PHA Change Completion Date05/07/2010
Hazard Identified - Toxic ReleaseYes
Hazard Identified - FireNo
Hazard Identified - ExplosionNo
Hazard Identified - Runaway ReactionNo
Hazard Identified - PolymerizationNo
Hazard Identified - OverpressureYes
Hazard Identified - CorrosionNo
Hazard Identified - OverfillingYes
Hazard Identified - ContaminationNo
Hazard Identified - Equipment FailureYes
Hazard Identified - Cooling LossYes
Hazard Identified - EarthquakeYes
Hazard Identified - FloodYes
Hazard Identified - TornadoNo
Hazard Identified - HurricaneYes
Process Controls - VentsNo
Process Controls - Relief ValvesYes
Process Controls - Check ValvesNo
Process Controls - ScrubbersNo
Process Controls - FlaresNo
Process Controls - Manual ShutoffsYes
Process Controls - Auto ShutoffsYes
Process Controls - InterlocksYes
Process Controls - AlarmsYes
Process Controls - Keyed BypassNo
Process Controls - Emergency AirNo
Process Controls - Emergency PowerNo
Process Controls - Backup PumpNo
Process Controls - GroundingNo
Process Controls - Inhibitor AdditionNo
Process Controls - Rupture DisksNo
Process Controls - Excess Flow DevicesNo
Process Controls - Quench SystemNo
Process Controls - Purge SystemNo
Process Controls - NoneNo
Mitigation Systems - SprinklersYes
Mitigation Systems - DikesNo
Mitigation Systems - Fire WallsNo
Mitigation Systems - Blast WallsNo
Mitigation Systems - Deluge SystemsNo
Mitigation Systems - Water CurtainsYes
Mitigation Systems - EnclosureNo
Mitigation Systems - NeutralizationNo
Mitigation Systems - NoneNo
Monitoring Systems - Process AreaYes
Monitoring Systems - PerimeterNo
Monitoring Systems - NoneNo
Changes Since PHA - Reduced InventoryNo
Changes Since PHA - Increased InventoryNo
Changes Since PHA - Process ParametersNo
Changes Since PHA - Process ControlsYes
Changes Since PHA - Process DetectionNo
Changes Since PHA - Perimeter MonitoringNo
Changes Since PHA - Mitigation SystemsYes
Changes Since PHA - None RecommendedNo
Changes Since PHA - NoneNo
Procedure Review Date12/03/2012
Training Review Date05/12/2010
Type of Training - ClassroomYes
Type of Training - On the JobNo
Competency Testing - Written TestsYes
Competency Testing - Oral TestsNo
Competency Testing - DemonstrationNo
Competency Testing - ObservationNo
Maintenance Review Date07/16/2007
Maintenance Inspection Date03/15/2008
Equipment TestedEvaporative Condenser CEB002
Management of Change Review Date12/15/2003
Pre-startup Review Date07/20/2007
Compliance Audit Date08/31/2010
Participation Plan Review Date11/18/2003
Hot Work Review Date11/30/2003
Contractor Safety Review Date11/20/2003
Contractor Safety Eval. Date05/18/2007
Confidential Business InformationNo

Prevention Program 3 Chemicals facility_Prevention_Program_3_Chemicals help link help link (Facility #1 : Compania Cervecera de Puerto R, RMP submission #1 : 2013-05-06, process #1 : Cold Block Ammonia Refrig, process NAICS code #1 : 31212, prev. program 3 #1, prev. program 3 chemical: all)
Process Chemical Record ID
1000050217

Prevention Program 3 Text facility_Prevention_Program_3_Text help link help link  
Prevention Program Description
The covered process starts with a liquid ammonia Receiver, located at the Compressor Room. From this Receiver ammonia is transferred to an externally located Separator. Liquid ammonia is pumped from the Separator to several end users, such as air coolers, vessel jackets, plate heat exchangers and air coolers. Evaporated ammonia is suctioned back to the compressor units, followed by condensation at the evaporative condensers located at the top of the Compressor Room. Condensed ammonia is then collected back at the Receiver.

Process NAICS facility_Process_NAICS help link help link  
NAICS Code311213: Malt Manufacturing

Accidents facility_Accidents help link help link  
Accident Date10/06/2007
Accident Time2335
Number of Chemicals1
Flammable Amount Total (lbs)0
Toxic Amount Total (lbs)18,074
Released Amount Total (lbs)18,074
Number of Deaths0
Number of Injuries71
Number Evacuated / Sheltered2,000
Total Property Damage$500,000
Environmental DamageNo
NAICS of Process Involved31212: Breweries
Release Duration (HHHMM)00330
Release Event - Gas ReleaseYes
Release Event - SpillNo
Release Event - FireNo
Release Event - ExplosionYes
Release Event - ReactionNo
Release Source - Storage VesselYes
Release Source - PipingYes
Release Source - Process VesselYes
Release Source - Transfer HoseNo
Release Source - ValveNo
Release Source - PumpNo
Release Source - JointNo
Wind Speed Unitsmiles/h
Temperature81
Atmospheric Stability ClassF
PrecipitationNo
Unknown WeatherNo
Workers Killed0
Responders Killed0
Public Killed (on-site)0
Workers Injured1
Responders Injured0
Public Injured (on-site)35
Property Damage (on-site)$500,000
Off-site Deaths0
Hospitalizations0
Number Requiring Medical Treatment35
Number Evacuated2,000
Number Sheltered In Place0
Property damage (off-site)$0
Environmental Damage - Fish/Animal KillsNo
Environmental Damage - DefoliationNo
Environmental Damage - Water ContaminationNo
Environmental Damage - Soil ContaminationNo
Initiating EventHuman Error
Contributing Factor - Equipment FailureYes
Contributing Factor - Human ErrorYes
Contributing Factor - Improper ProcedureYes
Contributing Factor - OverpressurizationNo
Contributing Factor - Upset ConditionNo
Contributing Factor - By-pass ConditionNo
Contributing Factor - MaintenanceNo
Contributing Factor - Process DesignNo
Contributing Factor - Unsuitable EquipmentNo
Contributing Factor - Unusual WeatherNo
Contributing Factor - Management ErrorNo
Contributing Factor - OtherHazard recognition and Training
Off-site Responders NotifiedNotified Only
Changes Introduced - Improved EquipmentNo
Changes Introduced - Revised MaintenanceNo
Changes Introduced - Revised TrainingYes
Changes Introduced - Operating ProceduresYes
Changes Introduced - Process ControlNo
Changes Introduced - Mitigation SystemsNo
Changes Introduced - Response PlanNo
Changes Introduced - Changed ProcessNo
Changes Introduced - Reduced InventoryNo
Changes Introduced - NoneNo
Changes Introduced - OtherPerformed a Process Hazard Analysis of a carbon dioxide system (not RMP covered)
Total RMP Accident Deaths0
Total RMP Accident Injuries71
Total RMP Accident Evacuated/Sheltering In Place2,000
Total RMP Accident Property Damage$500,000

Accident Chemicals facility_Accident_Chemicals help link help link (Facility #1 : Compania Cervecera de Puerto R, RMP submission #1 : 2013-05-06, accident #1, accident chemical #1)
Chemical IDAmmonia (anhydrous)
CAS number007664417
Chemical TypeToxic
Amount Released (lbs)18,074
Percent Weight (Within Mixture)100

Emergency Response Plan Info facility_Emergency_Response_Plan_Info help link help link  
Facility In Community PlanNo
Facility Own Response PlanYes
Specific Facility Response PlanYes
Inform. Procedures in Response PlanYes
Emergency Care in Response PlanYes
Plan Review Date01/09/2007
Response Training Date06/01/2007
Local Response AgencyLEPC Mayaguez Region
Local Response Agency Phone7878331188
Subject To - OSHA EAPYes
Subject To - OSHA HAZWOPERYes
Subject To - CWAYes
Subject To - RCRAYes
Subject To - OPAYes
Subject To - State EPCRAYes


Search Criteria Used